3.6 Setting DIP Switch

The DIP switch is present on the serial interface board.
The function of each switch is as shown below.
Interface board
mounting screws
CAUTION!
■ As for the setting of the serial interface, it gives priority to the setting of the memory
switch rather than the DIP switch as the factory default.
■ Consult with the dealer where the printer was purchased when the change of the DIP
switch setting is necessary.
Switch No.
Function
1
Communication condition DIP switch setting
setting method
2
Hand shake
3
Bit length
4
Parity check
5
Parity selection
6
Baud rate selection
7
8
INIT
Selecting baud rate
Baud Rate (bps)
2400
4800
9600
19200
38400, 57600 and 115200 bps can also be selected by a command, etc.
ON
XON/XOFF
7 bits
With parity
Even parity
See Table below.
Reset
Switch No.
6
OFF
ON
OFF
ON
— 19 —
DIP switch
OFF
Memory switch
setting
DTR/DSR
8 bits
None
Odd parity
Invalid
7
OFF
OFF
ON
ON
Initial
Settings
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF

Advertisement