Protech Systems PROX-1750 User Manual page 99

Pentium 4/pentium 4-m motherboard with vga / sound/ 2lan
Table of Contents

Advertisement

Appendix C Trouble Shooting
Slot Not Empty :
Indicates that a slot designated as empty by the EISA Configuration Utility
actually contains a board.
SYSTEM HALTED, (CTRL-ALT-DEL) TO REBOOT :
Indicates the present boot attempt has been aborted and the system must be
rebooted. Press and hold down the CTRL and ALT keys and press DEL.
Wrong Board in Slot
PLEASE RUN EISA CONFIGURATION UTILITY :
The board ID does not match the ID stored in the EISA non-volatile
memory.
Note: When this error appears, the system will boot in ISA mode, which
allows you to run the EISA Configuration Utility.
FLOPPY DISK(S) FAIL (80) :
Unable to reset floppy subsystem.
FLOPPY DISK(S) FAIL (40) :
Floppy type dismatch.
Hard Disk(S) Fail (80) :
Hard Disk Drive reset failed.
Hard Disk(S) Fail (40) :
Hard Disk Drive controller diagnostics failed.
Hard Disk(S) Fail (20) :
Hard Disk Drive initialization error.
Hard Disk(S) Fail (10) :
Unable to recalibrate fixed disk.
Hard Disk(S) Fail (08) :
Sector Verify failed.
Keyboard is locked out – Unlock the key :
BIOS detect the keyboard is locked. P17 of keyboard controller is pulled
low.
Page: C-6
Prox-1750G1/G2 USER
'
S MANUAL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prox-1750g1Prox-1750g2

Table of Contents