Installation
14
Approved Venting Configurations with a Horizontal Termination
and One 90° Elbow
If using a Snorkel Termination (14" or 36") add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
19' (max)
15 feet
10 feet
5 feet
0 feet
Travis Industries
Restrictor Position # 5
Restrictor
Position # 1
NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.
NATURAL GAS: Min. 2' Section Required
PROPANE (LP): Min. 3' Section Required
1 0 0 - 0 1 1 5 9
(for qualified installers only)
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
19' (max)
15 feet
10 feet
5 feet
0 feet
4 0 4 0 6 2 1