Quadra-Fire 7100FP-BK-B Owner's Manual page 62

7100fp epa certified woodburning fireplace installation and operation
Hide thumbs Also See for 7100FP-BK-B:
Table of Contents

Advertisement

1/2 in. (13mm)
clearance to
combustibles
must be
maintained.
Figure 11.5
Secure B-Vent to Fan Housing
with sheet metal screws
Return Air Grille
Securely Twist
Install with Louvers
Lock B-Vent to
pointed down
Adapter
Figure 11.6
4/12
2 x 4 Wall
Fan Housing
2 x 4 wall
Sheet Rock
Bracket
Can rotate
180
o
NOTICE: Secure the duct so that clearance to the fireplace
outer wrap is maintained. Tape all seams with aluminum
tape 1-1/4 in. (32mm) minimum width or as specified by local
codes.)
10. Seal all the way around the inside of the Return Air Grille
to prevent hot air being drawn back into the venting system
using gasketing supplied with the kit. Leave 1/4 in. (6mm)
clearance from all 4 outer edges. Trim excess gasketing.
See Figure 11.7
Figure 11.7
11. Install the variable speed wall rheostat (with setting on
"OFF") in a convenient location. This switch will control the
Heat-Zone fan operation.
12. Remove the Junction Box. Wire 110 VAC service TO the
wall rheostat and FROM the wall rheostat to the fan Junction
Box. Use wire nuts to secure the 110 VAC service wires to
the hot (black) and neutral (white) fan wires and screw the
110 VAC ground wire to the Junction Box. See Figure 11.8
13. Secure the Return Air Grille to the fan housing making
sure it is flush. The grille must be installed with the louvers
pointing down.
NOTICE: DO NOT UsE ADJUsTAblE REGIsTERs.
14. Complete the fireplace installations as per the instruc-
tions found in your Owner's Manual.
Figure 11.8
433-1390K
Leave 1/4" (6mm) clearance from
all 4 outer edges
White
Wire Clamp
Junction Box Removed
Junction Box
Wire Nuts
Page 62