E. Locating Fireplace & Chimney
Location of the fireplace and chimney will affect perfor-
mance.
• Install within the warm airspace enclosed by the building
envelope. This helps to produce more draft, especially
during lighting and die-down of the fire.
• Penetrate the highest part of the roof. This minimizes
the effects of wind loading.
• Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
• Minimize the use of chimney offsets.
• Consider the fireplace location relative to floor and ceiling
and attic joists.
• Take into consideration the termination requirements in
Section 8 and Section 9.
NOTICE: Locating the fireplace in a basement or in a
location of considerable air movement can cause intermittent
smoke spillage from fireplace. Do not locate fireplace near
frequently open doors
central heat outlets or returns
Recommended
Windward
Figure 5.2
Recommended Chimney Locations
4/12
Recommended
Location
Marginal
Location
Location
Not
Recommended
Location
Location NOT
Recommended
Multi-level Roofs
433-1390K
Leeward
Page 33