Connecting The Mains Supply Cable - Creda NewEra 79341S Assembly Instruction Manual

Tsr electric storage heaters

Advertisement

ENSURE THAT CABLE CLAMP
IS SECURELY ATTACHED TO
THE CHASSIS OF THE HEATER.
CONNECTING THE MAIN'S SUPPLY CABLE
7
WARNING
Remove the inner front panel; this carries on it's inner
face the front insulation slab. Handle this with care, the
insulation must not de damaged.
REMOVE ALL THE PACKING CARDBOARD FROM
INSIDE THE STORAGE BRICK COMPARTMENT, IF LEFT
INSIDE IT WILL BE SET ON FIRE WHEN THE HEATER
IS SWITCHED ON. ENSURE THAT ALL PACKAGING
MATERIAL IS REMOVED FROM THE BRICKS BEFORE
FITTING THEM.
79361/4/6S
79351/4/6S
79341/4/6S
MAINS TERMINALS
IMPORTANT: for earthing, loosen the earth screw sufficiently
to wrap the mains' earth wire around it between flat washer
and cup washer, and retighten the earthing screw.
Feed the mains cable through the cable clamp and make
connections as marked on the heater. Pull back any slack
through the clamp and tighten clamping screw. Make sure
clamp is tightening on outer sheath of cable and not on
individual conductors.
79341/4/6S
79351/4/6S
79361/4/6S
Some heater variants may have other charge
periods or acceptances. See heater rating
plate.
Charge
Rated
Period
Charge
7 hours
12 kWh
7 hours
18 kWh
7 hours
24 kWh