Optional Hose Position - Graco EP 24C932 Instructions Manual

Plural component, impingement mix, mechanical purge pour gun with throat seal liquid technology
Hide thumbs Also See for EP 24C932:
Table of Contents

Advertisement

Optional Hose Position

As shipped, fluid inlet swivel fittings point to rear of the
gun. If desired, use the following procedure to make the
fluid inlet swivel fittings point downward.
NOTICE
To prevent cross-contamination of gun's wetted parts,
do not interchange A component (isocyanate) and B
component (resin) parts.
1. Follow Pressure Relief Procedure, page 22.
2. Disconnect air quick coupler (AC). Use hex nut
driver to remove fluid manifold (AD).
AD
3. Disconnect signal cable.
4. Place a cap over the end of each hose. Disconnect
fluid hoses from inlet swivels (AE). Remove plugs
from optional inlets (AG).
AE
AG
F
. 10
IG
313872B
AC
TI14463a
TI2417a
AE
5. Apply thread sealant to plugs (AH), elbows (AJ),
and male threads of swivels (AE). Install
elbows (AJ) in optional inlets, facing down. See F
11. Install swivels in elbows. Be sure to install the A
swivel in the A side. Install plugs (AH) where swivels
had been. Torque all parts to 235-245 in-lb
(26.6-27.7 N•m).
F
. 11
IG
6. Connect the A hose to the A swivel and the B hose
to the B swivel.
7. Attach fluid manifold (AD) to gun. Torque fluid mani-
fold bolt to 20-30 in-lb (2.26-3.39 N•m).
8. Connect air quick coupler (AC).
Setup
.
IG
AH
AJ
AE
TI2646