Optional Hose Position - Graco Fusion CS Series Instructions Manual

For plural component, impingement mix air purge spray gun with clearshot liquid technology. for professional use only. for use with non-flammable foam and polyurea. not for use in explosive atmospheres.
Table of Contents

Advertisement

Optional Hose Position

Optional Hose Position
Fluid inlet swivel fittings point to rear. If
desired, these positions can be changed so
hoses point downward.
CAUTION
To prevent cross-contamination of gun's
wetted parts, do not interchange A
component (isocyanate) and B component
(resin) parts.
1. Follow Pressure Relief Procedure, page
17. Also relieve system pressure, see
proportioner manual.
2. Disconnect air (D) and remove fluid
manifold (M).
M
F
. 19
IG
18
3. Disconnect fluid hoses from inlet swivels
(A, B). Remove fluid valve assemblies.
Remove plugs from optional inlets (P).
F
. 20
IG
4. Apply thread sealant to plugs (1e), elbows
(35), and male threads of fluid valve
assemblies. Install elbows (35) in optional
inlets, facing down. Install fluid valve
assemblies in elbows. Be sure to install A
fluid assembly in A side. Install plugs where
swivels had been. Torque all parts to
235-245 in-lb (26.6-27.7 N•m).
D
TI11330a
F
. 21
IG
5. Connect A and B hoses to A and B swivels.
6. Attach fluid manifold. Connect air. Return
gun to service.
B
P
TI11329a
A
1e
TI12085a
312666W