Remove Front End - Graco EP 24C932 Instructions Manual

Plural component, impingement mix, mechanical purge pour gun with throat seal liquid technology
Hide thumbs Also See for EP 24C932:
Table of Contents

Advertisement

Remove Front End

NOTICE
Proper attachment of front end is critical. Do not
operate gun if front end is loose or not snug against
body. Improper attachment can cause slow leaks.
1. Perform Pressure Relief Procedure, page 22.
2. Flush Gun, see page 25.
3. Perform Bleed Throat Seal Liquid Cartridge pro-
cedure on page 24 to bleed all fluid from cartridge or
replace with empty cartridge. TSL will spill if any
fluid remains in cartridge after this step.
4. Disconnect air quick coupler (AC). Use hex nut
driver to remove fluid manifold (AD).
AD
5. Disconnect signal cable.
6. Rotate fluid housing (AK) 45 degrees counterclock-
wise to disengage fluid housing slots.
AK
313872B
7. Pull fluid housing away from gun body to remove. If
fluid housing cannot be removed perform the follow-
ing steps.
a. Attach air quick coupler.
b. Pull and release the trigger or press and release
c. Remove fluid housing.
d. Disconnect air quick coupler.
8. Disengage purge rod from ball socket in piston shaft
then remove purge rod.
9. Inspect fluid housing o-rings for wear or damage.
Replace if necessary.
AC
TI14463a
ti14479a
the red button on the solenoid valve.
Repair
ti14481a
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep 313872bEp ti14450aEp 24c933Ep 24c934Ep 257999

Table of Contents