NOTE: The Humidification setpoint can range from 10% to 60% in 5% increments. The default
humidification setpoint is 50%.
3. Press Done key to save your changes and return to the Home screen.
4. Press Cancel key to return to Home screen without saving any changes.
Humidification Control
If the humidification control has been enabled, the Comfort Control attempts to control to this
humidification setpoint by turning on the humidifier.
Frost Control
TM
If your AccuLink
humidifier, you can use the frost control feature to control window condensation during the heating
season. Frost control works by reducing humidification when conditions indicate that condensation
or frost can occur.
The degree of frost control is determined by the setting you choose between 0 and 10. Press More
key until you come to the frost setting screen. The display shows FROST and a number from 0 to 10.
When the factory setting (5) results in too much condensation or frost on the windows, lower the
setting. When the air seems too dry, raise the setting.
communicating system is equipped with an outdoor temperature sensor and a