Warning: The drain line from the TPR valve must be in copper. A Rheem mains pressure
water heater must not
relief valve that complies with AS 1357.1. Under no circumstances block the outlet of this
valve or its drain pipe.
DIAGRAM 2
PRESSURE LIMITING VALVE
If the water supply pressure exceeds the requirements of Table 5.2 AS/NZS 3500.4, a pressure
limiting valve with a maximum setting of 500 kPa is to be fitted in the installation.
SAFE TRAY
The water heater must be installed with a properly drained safe tray where there is the possibility
of water damage to furniture, carpets or building. Failure to do so may jeopardise any warranty
claim.
EARTHQUAKE RESTRAINTS
All water heaters must be restrained to protect against seismic forces. Refer to the Zealand
Building Code for acceptable solutions.
be installed and operated without a suitable temperature and pressure
- 6 -