Chapter 8. Alarm I/O Connector - Planet IVS-H125 User Manual

H.264 internet video server
Hide thumbs Also See for IVS-H125:
Table of Contents

Advertisement

Some features of the Camera can be activated by an external sensor that senses physical
changes in the area device is monitoring. These changes can include intrusion detection or certain
physical change in the monitored area. For examples, the external sensor can be a door switch or
an infrared motion detector. These devices are customer provided, and are available from dealers
who carry surveillance and security products. Electrically, they must be able to provide a
momentary contact closure.
This device provides a general I/O terminal block with one digital input and one output for device
control. Pin 2 and 3 can be connected to an external sensor. The input voltage will be monitored
from the initial state 'LOW'. If the external sensor need 12VDC power, then it can connect to Pin1
(50mA maximum). The Alarm Output of pin 3 and 4 can be used to turn on or off the external
device. The pin5 and 6 are connected to RS485 interface.
I/O
Connector
User can refer to the schematic below to make a proper
connection between I/O connector and external sensor and
output device.
User's Manual of IVS-H125 Series
Alarm I/O Connector
Pin
1
2
3
4
5
6
83
Chapter 8.
Function
12VDC power supply
(50mA maximum)
Digital Input
GND
Alarm Output
RS485 data +
RS485 data -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ivs-h125p

Table of Contents