5. Unscrew the filter and remove it.
1
6. Remove fluff and objects from the
pump.
7. Make sure that the impeller of the
pump can turn. If this does not occur,
contact the service centre.
8. Clean the filter under the water tap and
put it back in the pump.
9. Make sure that you tighten correctly the
filter to prevent leakages.
2
10. Close the drain pump door.
Clean the inlet valve filter
It could be necessary to clean the filter
when:
2
1
• The appliance does not fill with water.
• The appliance fills with the water for a
long time.
Warning! Disconnect the mains plug
from the mains socket.
To clean the filter:
1. Close the water tap.
2. Remove the inlet hose behind the appli-
ance.
3. Clean the filter in the valve with a stiff
brush or a towel.
4. Install again the inlet hose. Make sure
that the couplings are tight to prevent
leakages.
5. Open the water tap.
Emergency drain
Because of a malfunction, the appliance
cannot drain the water.
If this occurs, do steps (1) through (5) of 'To
clean the drain pump'.
If necessary, clean the pump.
When you drain the water with the emer-
gency drain procedure, you must activate
again the drain system: