6.

ACCESSORIES

6.1
BATTERY PACK MODULE (OPTIONAL)
The battery pack module is a field-installable assembly that provides
approximately eight hours of uninterrupted operation. A monitoring circuit
ensures that the two 12V batteries charge within 12 hours and then switch to
trickle charge to ensure maximum charge without battery damage. An alarm
warns the operator when batteries are low.
FIGURE 6-1
6.1.1
BATTERY PACK MODULE INSTALLATION
1. Open the access door of the detection unit.
2. Disconnect the AC power plug from the power supply module.
3. Remove the three screws that hold the controller module cover.
4. Remove the four acorn nuts from the package.
5. Install the battery pack module with the acorn nuts.
6. Disconnect the power supply module connector from the controller
circuit board. (See Figure 6-1)
7. Reconnect the power supply and battery pack modules. (See Figure 6-1)
8. Reassemble the system and test.
6.2
AC & DC CONTROL
6.2.1
AC CONTROL
To connect an external alarm, a locking device, a VCR/video monitor or
other AC component, follow Figure 6-2. The optically-isolated triac output
conducts only when the red Alarm light is illuminated. Control should not
exceed 48Vrms and 100mA. The output is electrically isolated from ground.