IR ANALYSIS <on>, will appear on LCD. Press the minus (–) touchpad to
disable or (+) touchpad to activate.
Press ACCESS for the next adjustment or OPERATE to resume normal
operation.
3.5.14
LANGUAGE
LANGUAGE <current language setting>, appears on the LCD. If the user is
authorized to change the language setting, the user may scroll through the
language selections using the + / - touchpads. Choose from:
LCD MESSAGE
LANGUAGE ENGLISH
IDIOMA ESPANOL
DIL TURKCE
SPACHA DEUTSCH
Press ACCESS for the next adjustment or OPERATE to resume normal
operation.
3.5.15
RX BALANCE
RX BAL < RX balance number >, appears on LCD. RX balance refers to the
balance level of the receiving antennas. Any number less than 50 is
acceptable. A number greater than 50 will elicit the message, RX BAL #, and
the pinpoint lights within the problem zone will illuminate. Should this occur,
ensure that there is no large metal object adjacent to the PD 6500i. Then,
ensure that the balance number has fallen below 50 and the corresponding
pinpoint lights are off. (Refer to section 5.4 for more help in resolving this
issue if necessary)
Press ACCESS for the next adjustment or OPERATE to resume normal
operation.
3.5.16
SYNCHRONIZATION
Synchronization is factory preset to MASTER. Refer to Section 2.4 for a
more detailed explanation of synchronization.
SYNC MASTER, provides the PD 6500i with a self-generated synchronization
from the power line.
SYNC SLAVE, synchronizes the PD 6500i from a second signal on the
sync terminal located on the left edge of the transmitter controller board.
©2003 GARRETT METAL DETECTORS
GARRETT PD 6500i
USER MANUAL
LANGUAGE
ENGLISH
SPANISH
TURKISH
GERMAN
28
PN 1532010 REV A