2.2.1
POWER CORD WIRING DESCRIPTION
The PD 6500i (Model 11684xx) includes a standard American ground power
cord. To replace or remove plug, or to hard wire to an AC junction box, use:
The PD 6500i (Model 1168420) (INTERNATIONAL) includes a European
power cord. To replace or remove plug, or to hard wire to an AC junction
box, use:
2.2.2
STABILIZING
For proper stability, the PD 6500i should be firmly secured to the ground.
Anchor the unit to the floor, using the 1/4" mounting holes located at the base
of each panel. Position the PD 6500i in the desired location. Using the panels
as guides, mark and drill holes, then secure the walk-through using the
appropriate mounting devices. Tighten only to prevent rocking. DO NOT
over-tighten! As an option, stabilizer bases or adhesive floor mounting plates
are available for securing the PD 6500i to the floor without drilling.
2.3

PLACEMENT PROCEDURE

1. Place assembled unit (For Assembly, See Section 2.2) in final position at
2. Connect to power source.
3. Program / Calibrate unit. (See Section 3)
4. Check for interference and troubleshoot. (See Section 5)
5. Test. (See Section 2.3.1 and 2.3.2)
CAUTION
For multiple PD 6500i operation (units within 25' to 100' of each other
depending on sensitivity setting), additional power requirements and
installation adjustments are necessary to avoid crosstalk (interference)
among units. (See sections 2.1.3 and 2.4 for multiple unit operation)
2.3.1
OPERATIONAL TESTING
Once the PD 6500i is calibrated, a SELECTED TEST OBJECT can be used
as a substitute for the forbidden object in subsequent routine verifications.
A SELECTED TEST OBJECT is an object similar in size, shape and material
composition to the smallest forbidden target and is considered an acceptable
means of verifying calibration.
©2003 GARRETT METAL DETECTORS
GARRETT PD 6500i
USER MANUAL
Green
Black
White
Green/Yellow
Brown
Blue
checkpoint location.
To Ground
To line Hot
To line Neutral
To Ground
To line Hot
To line Neutral
19
PN 1532010 REV A

Advertisement