Master Code reset to Factory 「12345」 and Delete All User Codes
Insert the jumper RESET
successful
(after 5 seconds)
Insert the jumper to 2-3 positions.
6. Wiring diagram:
Power Supply
Fail-Safe
Locking Device
Power Supply
Fail-Secture
Locking Device
For DC use only
Note:
The suggested wire gauge is #22~26 AWG.
Distance between the keypad and controller board: Maximum 50 M (cable#22~26 AWG).
The door strike must have a vartistor or a diode across the door strike terminals to
suppress the back EMF of the strike - failure to do so will damage the relay contacts and
electronic components.
Warranty:
The product is warranted against defects in material and workmanship while used in normal
service for a period of 1 year from the date of sale to the original customer .GEM policy is one
of continual development and improvement , therefore GEM reserves the right to change
specifications without notice.
Copyright © Gianni Industries, Inc. All Rights Reserved.
P-MU-DG100-5C Ver. C Published on 2009.06.15
1-2 position 5 audible beeps Reset Master Code
5 audible beeps Delete All User Codes
Vin
Push Button
Vin
Push Button
For AC/DC
Vout
+
PB
-
+
N.O.
-
COM
RC
N.C.
R
P
P
Reset
Vout
PB
+
-
+
N.O.
-
COM
RC
R
N.C.
P
P
Reset
Page: 3/ 3
Return
Blue
Red
Black
White
Green
Reset
Master Code
to
1
Factory, or remove all
2
3
stored PIN codes.
Blue
Red
Black
White
Green
Reset
Master Code
to
1
Factory, or remove all
2
stored
PIN codes
.
3