Download Print this page

Gianni Industries GEM DG-100 Operation Manual

Split digital keypad

Advertisement

Quick Links

Ⅰ. Features
1.
Memory volume up to 99 PINs
2.
Split controller and keypad for high security
3.
Up to 29-digit-fuzzy-code password protected design
4.
Deftly dimension for narrow jamb
5.
1 LED indicator & buzzer for status indication
6.
Fully programmable via keypad
7.
Lockout function
8.
Metal casing for enhanced safety and durability
9.
Keypad with beep sound
Ⅱ. Specifications
Operating Voltage 12VDC
Current Draw Holding: 15mA, Pull in: 70mA @12VDC
Relay Electric Current 1A MAX @24VDC ;0.5A @ 120VAC
Memory Volume
Relay Strike Time 01~99 seconds or Toggle Mode (00)
LED Status Indication 3 colors LED indicator display (Red/Yellow/Green)
Lockout Function
Ambient Humidity 5%~95% (Non-condensing)
Operating Temperature -20℃~+70℃
Copyright All Rights Reserved.
P-MU-DG100-4C Ver.D Publish:2009.12.02
DG-100 Split Digital Keypad
Operation Manual
Keypad 6X2 matrix keypad (0~9,*,#)
Output Relay(Dry contacts: N.O./N.C./Com.)
99 PINs
*000:master code
*001~099:PINs (user codes)
*100:relay strike time
The controller will be lockout for 60 seconds upon 30 consecutive master
codes or invalid PINs attempt. (Keypad without beep sound)
Non-volatile memory allows remaining all setting codes in the event of total
EPROM
power failure.
Page: - 1 -/ 4

Advertisement

loading

Summary of Contents for Gianni Industries GEM DG-100

  • Page 1: Specifications

    DG-100 Split Digital Keypad Operation Manual Ⅰ. Features Memory volume up to 99 PINs Split controller and keypad for high security Up to 29-digit-fuzzy-code password protected design Deftly dimension for narrow jamb 1 LED indicator & buzzer for status indication Fully programmable via keypad Lockout function Metal casing for enhanced safety and durability...
  • Page 2: Operation Instruction

    Note: 1. “0000”, “1234” and any master code cannot be used for PINs 2. Up to 29-digit-fuzzy-code password protected design e.g. Press 59632548745233058403256905194→open the door (The valid PINs are “5194”) Copyright © Gianni industries, inc. All Rights Reserved. P-MU-DG100-4C Ver. D Published on 2009.12.02 Page: - 2 -/ 4...
  • Page 3 2. Master Code reset to default value“1234” 3. Clear all PINs (wait after 5 seconds) (5 beeps) 4. Insert the jumper back into 2-3 Copyright © Gianni industries, inc. All Rights Reserved. P-MU-DG100-4C Ver. D Published on 2009.12.02 Page: - 3 -/ 4...
  • Page 4: Wiring Diagram

    1 year from the date of sale to the original customer. The GEM policy is one of continual development and improvement; therefore GEM reserves the right to change specifications without notice. Copyright © Gianni industries, inc. All Rights Reserved. P-MU-DG100-4C Ver. D Published on 2009.12.02...