Handset Connection - Furuno FM-2721 Operator's Manual

Marine vhf radiotelephone
Table of Contents

Advertisement

1.3 Handset Connection

Take appropriate measures to ensure water does not leak through hole in bulkhead made for handset cable.
10P cable between the hanger and transceiver unit
10P cable (supplied, 5 m) should be fabricated as below.
6
80
Connect to the appropriate
Anticorrosive
terminal block in the hanger.
Sheath
Connect to the terminal block #16
in the hanger.
Drain wire
Cable Fablication
Pass the above cable through the entrance hole at the back of the hanger, and attach to the appropriate block.
Cover the hole with soft putty from the inside of the hanger.
Handset cable
Connect to the connector at the bottom of the hanger.
GRN/
BLU/
ORG/
BRW RED ORG YEL
WHT
WHT
WHT
1
2
3
4
5
6
7
9
10
11 12
13
14 15
GRN BLU PPL WHT BLK Drain
WHT
BLK
(B)
(B)
Terminal Block Arrangement
9
YEL/
BLK
Push the appropriate switch down
to insert/pull out the cable.
8
Drain wire should be covered by
vinyl sheath, or soldered to the
16
shield in the cable to be grounded.
Not used cables: Cutt off.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents