Location; New York City, New York (Mea); Commonwealth Of Massachusetts Requirements - Lennox Hearth Products CI1500DVF Installation Instructions Manual

Direct-vent serefina series
Table of Contents

Advertisement

WARNING: This appliance must be properly connected to a venting
system. Operation of this gas appliance when not connected to
a properly installed and maintained venting system can result in
carbon monoxide (CO) poisoning and possible death.
Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning are similar to the flu with headaches, dizziness and/or
nausea. If you have these signs, obtain fresh air immediately. Have
the appliance serviced by a qualified technician as it may not be
operating correctly. Some people are more affected by carbon
monoxide than others. These include pregnant women, people
with heart or lung disease or anemia, those under the influence of
alcohol, and those at high altitudes.
Do not place clothing or other flammable materials
on or near this appliance.
AVERTISSEMENT
Surveiller les enfants. Garder les vêtements, les
meubles, l'essence ou autres liquides à vapeur inflam-
mables lin de l'appareil.
Failure to comply with the installation and operating
instructions provided in this document will result in
an improperly installed and operating appliance,
voiding its warranty. Any change to this appliance
and/or its operating controls is dangerous. Improper
installation or use of this appliance can cause seri-
ous injury or death from fire, burns, explosion or
carbon monoxide poisoning.
Children and adults should be alerted to the hazards
of high surface temperatures. Use caution around
the appliance to avoid burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Note: An Optional Screen Panel for the glass is avail-
able (see Homeowners Manual for ordering informa-
tion).

LOCATION

In selecting the location, the aesthetic and functional use of the
appliance are primary concerns. However, vent system routing to the
exterior and access to the fuel supply are also important. Consider-
ation should be given to traffic ways, furniture, draperies, etc., due
to elevated surface temperatures.
6
WARNING
WARNING
WARNING
Considerations Should Include:
• Existing Chimneys
• Aesthetic Considerations
• Roof Design (Rafter Locations and Roof Pitch)
• Room Traffic
• Proximity to Combustibles
• Proximity for Optimum Heat Transfer
• Electrical Wiring (if optional blower is installed)
The installation of this stove will require some research. Once your
options are determined, consult with your local building department
who will be able to give you the necessary installation requirements for
your area (Is a building permit required?, Rooms where installation may
not be allowed?, etc.).

NEW YORK CITY, NEW YORK (MEA)

Installation of these appliances are approved for installation in New York
City in the US state of New York.

COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS

(Massachusetts Approval #G1-1105-11)
These appliances are approved for installation in the US state of Mas-
sachusetts if the following additional requirements are met:
• Install this appliance in accordance with Massachusetts Rules and
Regulations 248 C.M.R. Sec. 5.08 2(a) through 2(e).
• Installation and repair must be done by a plumber or gas fitter licensed
in the Commonwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches (92
centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, horizontal terminations installed
less than seven (7) feet above the finished grade must comply with the
following additional requirements:
• A hard wired carbon monoxide detector with an alarm and battery
back-up must be installed on the floor level where the gas fireplace
is installed. The carbon monoxide detector must comply with NFPA
720, be ANSI/UL 2034 listed and be ISA certified.
• A metal or plastic identification plate must be permanently mounted to
the exterior of the building at a minimum height of eight (8) feet above
grade and be directly in line with the horizontal termination. The sign
must read, in print size no less than one-half (1/2) inch in size, GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.