Step 8 Install Lower Access Door; Step 9 Install Venting - Lennox Hearth Products CI1500DVF Installation Instructions Manual

Direct-vent serefina series
Table of Contents

Advertisement

Wiring - Optional Forced Air Blower Kit:
BK-CI (see Figure 11 for wiring diagram) - (An optional field-provided
outletbox/J-Box may also be used). Install the blower kit according to
the installation instructions provided with the kit.
The power cord must be plugged directly into a properly
grounded three-prong 120 volt, 60 hz wall receptacle. Do
not cut or remove the grounding prong from this plug. Do
not route power cord under or in front of appliance.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat et
dangereux.
Blower Wiring
Diagram
Blower
Mounting
Bracket
Figure 11
Fan Disc
14
WARNING
Power Cord
Blower
Assembly
(Shown
Rotated 90
Degrees CCW)
Black
Black
White
White
Black
Rheostat
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Step 8: INSTALL LOWER ACCESS DOOR .
Install the lower access door by inserting the tabs on the door sides
into the corresponding holes on the brackets on the stove bottom
(see Figure 12 below)
The lower access door hinges open to access Valve Controls
Figure 12
Step 9: VENTING SYSTEM INSTALLATION
INSTALL VENTING COMPONENTS PER VENT MANUFACTURERS
INSTRUCTIONS
The vent system may not service multiple appliances, and must never
be connected to a flue serving a solid fuel burning appliance.
CAUTION: Under no circumstances should these appliances be
vented to other rooms or buildings. These appliances must only be
vented to the outside. Vent terminations shall not be recessed into
a wall or siding.
IMPORTANT: Do not exceed the maximum horizontal run allowed
(see Figures 13 and 14).
Support Brackets - Install vent support brackets as specified in the
vent manufacturers instructions and the National Gas Fuel Code, USA
- NFPA 54 / ANSI Z223.1, 7.6.5 Support of Gas Vents. Gas vents shall
be supported and spaced in accordance with their listings and the (vent)
manufacturer instructions.
General Information: These instructions should be used as a guideline
and do not supersede local codes in any way. Install vent according
to local codes, these instructions, the current National Fuel Gas Code
(NFPA 54 / ANSI-Z223.1) in the USA or the current standards of
CAN/CSA-B149.1 in Canada.
These stoves are designed, tested and listed for operation and installation
with, and only with, "Security Secure Vent
Components (co-axial DV pipe with 4" inner and 6-5/8" outer diameter).
These approved vent system components are labeled for identification. DO
NOT use any other manufacturer's vent components with these appliances.
These stoves must be vented directly to the outside.
Lower Access
Door
" or "Simpson Dura Vent" brand
TM