Step 16 Install Top, Trivet & Ash Lip - Lennox Hearth Products CI1500DVF Installation Instructions Manual

Direct-vent serefina series
Table of Contents

Advertisement

Burner Adjustment
Initially, always position the air shutter to the factory setting as shown
in Figure 34 (adjustment rod is located in the lower control area). This
can be done by moving the adjustment rod up or down accordingly.
Allow the burner to operate for at least 15 minutes. Observe the flame
continuously. If it appears weak or sooty as previously described,
adjust the air shutter to a more open position until the desired flame
appearance is achieved.
The adjustment rod and associated adjustable air shutter is patented
technology. Flame adjustments can be made quickly and accurately to
taste without the need of disassembling the appliance and waiting for
30 minutes after each adjustment.
Burner Air Shutter Adjustment
Burner Tube
Air Shutter
Adjustment Rod Down
(full open position)
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model
CI1500DVF
CI2500DVF
Figure 34
Air Shutter Adjustment Guidelines:
If the burner flame appearance differs greatly from what is shown
on Page 21 (see Figure 33), some adjustment from standard for the
air shutter gap may be necessary (to compensate for variables in the
installation and fuel such as, BTU value / composition, gas pressure,
specific gravity of gas, altitude, etc.).
The following chart is provided to aid you in achieving the correct air
shutter adjustment for your installation.
Air Shutter Adjustment Guidelines:
Amount of
Primary Air
If air shutter is
Flame will
closed too far
be yellow
If air shutter is open
Flame will
too far
be blue
Table 9
22
Adjusting Set Screw
Adjustment Rod Up
(1/8" Open Position)
Ref. Air shutter Patent:
U.S. Pat. 5,553,603
Natural
Propane
Gas
Gas
5/16"
5/8"
(7.93 mm)
(15.9 mm)
1/2"
5/8"
(12.7 mm)
(15.9 mm)
Flame Color
Air Shutter
Adjustment
Air shutter gap should be
increased
Air shutter gap should be
decreased
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
When satisfied that the appliance operates properly, proceed to finish
the installation. Leave the control knob in the ON position and the
on/off switch in the OFF position.
Step 16. INSTALL STOVE TOP, TRIVET AND ASH LIP
A. Place the cast iron top into position on the stove top (See Figure 35).
Place the trivet into the recess on the cast iron top (See Figure 35).
The cast iron stove top is very heavy and may
require a minimum of two people to lift; one person
on each side (the CI1500 series cast top weighs
~20 pounds and the CI2500 series cast top weighs
~40 pounds).
Stove Cast Iron Top
Figure 35
B. Locate the ash lip from packaging (Step 2). Remove the 2 bolts from
the tapped holes in the ash lip. Align the ash lip below the firebox as
shown in Figure 36 (the tapped holes in ash lip should align with
corresponding slots below firebox). Reinstall the 2 bolts that were
removed from the ash lip (finger tight only. If a tool is used, be careful
not to overtighten).
Ash Lip
Figure 36
CAUTION
Trivet
Trivet

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ci2500dvf

Table of Contents