Midea Inverter Split-type Room Air Conditioner Owner's Manual

Inverter split-type room air conditioner

Advertisement

OWNER S MANUAL

Inverter Split-type Room Air Conditioner
Please read the operating instructions and safety precautions carefully
and thoroughly before installing and operating your room air conditioner.

Advertisement

Table of Contents
loading

Summary of Contents for Midea Inverter Split-type Room Air Conditioner

  • Page 1: Owner S Manual

    OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
  • Page 2 SOCIABLE REMARK The follow contents apply only the countries of Europe. DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • Page 3: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ..................PARTS NAMES ..................... OPERATING TEMPERATURE ................MANUAL OPERATION ..................ADJUSTING AIR FLOW DIRECTION..............HOW THE AIR CONDITIONER WORKS..............OPTIMAL OPERATION ..................MAINTENANCE....................... OPERATION TIPS ....................TROUBLESHOOTING TIPS................... Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
  • Page 5 ! CAUTION When the air filter is to be Turn the main power off Ventilate the room well when when cleaning or maintain- used together with a stove, removed, do not touch the metal parts of the unit. ing the product. etc.
  • Page 6: Parts Names

    PARTS NAMES INDOOR UNIT INDOOR UNIT Front panel frame Front panel Air inlet Air filter Horizontal air flow grille Vertical air flow louver Room temperature sensor Display panel Infrared signal receiver Air outlet Remote controller OUTDOOR UNIT Drain hose, refrigerant connecting pipe Connective cable Air inlet Stop valve...
  • Page 7: Operating Temperature

    OPERATING TEMPERATURE Mode Drying operation Cooling operation Heating operation Temperature >17 C Room temperature >10 C <30 C 50 C 50 C -15 C 34 C Outdoor temperature ( -15 C 50 C:For the models with low temperature cooling system) CAUTION: 1.
  • Page 8: Adjusting Air Flow Direction

    ADJUSTING AIR FLOW DIRECTION Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. To set the vertical air flow(Up--Down) direction Perform this function while the unit is in operation.
  • Page 9: How The Air Conditioner Works

    HOW THE AIR CONDITIONER WORKS AUTOMATIC OPERATION ECONOMIC (SLEEP) operation When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature. Temperature The air conditioner will control room temperature 1 hour...
  • Page 10: Maintenance

    MAINTENANCE WARNING It is necessary to stop the air conditioner and dis- connect the power supply before cleaning. Cleaning the indoor unit and remote controller CAUTIONS Use a dry cloth to wipe the indoor unit and remote controller. A cloth dampened with cold water may be used the indoor unit if it is very dirty.
  • Page 11 MAINTENANCE 4. Remove the air freshening filter from its support frame (The installation and removing method of the air freshening filter is different depending on the models, Air freshening filter see the pictures marked on the left. Clean the air freshening filter at least once a month, and replace it every 4-5 months.
  • Page 12: Operation Tips

    OPERATION TIPS The following events may occur during normal operation. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 13 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. Heating mode (For cooling and heating models only) The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation.
  • Page 14: Troubleshooting Tips

    TROUBLESHOOTING TIPS Malfunctions and Solutions Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION/RUN indicator or other indicators flash rapidly (5 times every second) and this flash can't be fixed by disconnecting the power, and then connect it in again. Trouble Fuse blows frequently or circuit breaker trips frequently.
  • Page 15 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. CS383-U1 202000190149 20100630...

Table of Contents