HP 5920 Series Installation Manual page 39

5920&5900 switch series
Hide thumbs Also See for 5920 Series:
Table of Contents

Advertisement

transceiver modules with optical fibers. If the IRF member switches are all in one equipment room, choose
twisted pair/SFP+/QSFP+ cables. For more information about available SFP+/QSFP+ cables and
transceiver modules, see
The following subsections describe several HP recommended IRF connection schemes, and all these
schemes use a ring topology.
Connecting the IRF member switches in one rack
Use short-haul and long-haul SFP+ cables to connect the IRF member switches (four switches in this
example) in a rack as shown in
in the same order as connected in the rack.
Figure 47 Connecting the switches in one rack
1
2
3
4
Figure 48 IRF fabric topology
Connecting the IRF member switches in a ToR solution
You can install IRF member switches in different racks side by side to deploy a top of rack (ToR) solution.
Figure 49
shows an example for connecting four top of rack IRF member switches by using SFP+/QSFP+
cables, and SFP+/QSFP+ transceiver modules, and optical fibers. The topology is the same as
48.
"SFP+
port" and
"QSFP+
Figure
47. The switches in the ring topology (as shown in
35
port."
Figure
48) are
Figure