ASSEMBLY
Battery
The battery is a standard part for this generator.
WARNING:
Battery posts, terminals, and related accessories contain
lead and lead compounds.
The battery is disconnected and the battery cables and blue coupler
harness are clamped twist clipped into the battery tray for shipment.
1.
Remove the maintenance cover (see page
2.
Remove the battery strap from the bottom hook, and then remove
the battery.
3.
Only remove the battery cables from the twist clip.
Make sure that the 4-pin blue coupler harness is secured with the
twist clip.
Return the battery to its tray.
4.
Remove the protective cover from the battery positive ( ) terminal,
and connect the positive ( ) cable to the battery positive ( )
terminal. Move the protective cover back over the positive ( )
terminal.
5.
Connect the negative ( ) cable to the battery negative ( ) terminal.
6.
To secure the battery, hook the battery strap onto the bottom hook
of the generator.
BATTERY CABLES
POSITIVE ( ) CABLE
NEGATIVE ( ) CABLE
86
Wash hands after handling.
4-PIN BLUE COUPLER HARNESS
TWIST CLIP
PROTECTIVE COVER
57
).
BATTERY STRAP
BOTTOM HOOK