SIDE BURNER TROUBLESHOOTING

For the Platinum Series II 3200 & 3400
WARNING: Before attempting any troubleshooting
steps, all gas controls and supply valves should be in
the OFF position.
Problem
Side burner does not light.
Flame is low in HIGH position.
Flame is very yellow in conjunction with
the smell of gas,
OR
Burner makes popping noise in conjunction
with the smell of gas.
Push button ignition does not work.
Flame is large or erratic.
Check
Is gas supply off?
Is fuel hose bent or kinked?
Inspect burner ring slots for
obstructions.
Inspect burner base for
obstructions.
Does burner light with a match?
Is the burner ring correctly
installed?
15
Cure
Turn supply on.
Straighten hose.
Clean if necessary.
If match lights burner, check
igniter (see Side Burner
Maintenance).
See Side Burner Maintenance
for correct assembly.