  • Page 1 For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.com 7212860100R01...
  • Page 2: Table Of Contents

    CAUTION: Procedures and tech- niques which, if not carefully followed, will result in damage to the equip- ment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
  • Page 3: Welcome & Congratulations

    Welcome & Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex, the world leader in electric fireplaces. Please carefully read and save these instructions. CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.
  • Page 4: Important Instructions

    ⑤ The appliance is not intended inside. Do not use in areas where for use by young children or gasoline, paint, or flammable infirmed persons without supervi- liquids are used or stored. sion. www.dimplex.com...
  • Page 5: Save These Instructions

    IMPORTANT INSTRUCTIONS ⑭ Do not modify the electric WARNING: Remote control fireplace. Use it only as described contains small batteries. Keep in this manual. Any other use not away from children. If swallowed, recommended by the manufactur- seek medical attention immedi- er may cause fire, electric shock ately.
  • Page 6 · Consult the dealer or an experienced radio/TV technician for help. Operation is subject to the following two conditions: (1) this device may not cause interference and (2) this device must accept any interference, including interference that may cause undesired operation of the device. www.dimplex.com...
  • Page 7: Quick Reference Guide

    Quick Reference Guide Figure 1 ① The electrical information regarding your electric fireplace can be found on the rating label located [7.1 in.] on the front of the unit, behind the glass. Before installation, please record your fireplace's serial number below for future reference.
  • Page 8: Fireplace Installation

    WARNING: Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons. WARNING: To reduce the risk of fire, do not store or use gaso- www.dimplex.com...
  • Page 9: Wiring

    Fireplace Installation you are ready to install the power supply through a cable fireplace. clamp (not included) and the hole in the electrical cover Wiring bracket. WARNING: To reduce the risk 3. Remove the two covers off of of fire, electric shock or injury to the unit at the front to access persons, always use a licensed the wire connections.
  • Page 10 (L2) on the unit. voltage. (See Installation - • Connect the white wire (N) Voltage Selector Switch) from the unit to the neutral wire from the power supply. www.dimplex.com...
  • Page 11: For Bathroom Use

    Fireplace Installation For 240V Installations VOLTAGE SELECTOR SWITCH CONTROL PCB THERMAL CUTOUT 240 V~ / 60 HZ Power Supply (Breaker Panel) See Options Below Different Heat Control Options 3. For installation with a 2. For No Heat installations 1. Regular installation Heat Disconnect Switch leave L2 unconnected with attach Neutral and L2 to...
  • Page 12: Voltage Selector Switch

    Figure 5. Using a flat headed screwdriver change the switch to correspond to the incoming voltage: 240V - Figure 9 Mounting hole Figure 8 2 x 8 Framing Wall surface Mounting hole www.dimplex.com...
  • Page 13: Surface Mount Installation

    Fireplace Installation 230 position, 120V - 115 position. drywall, install the supplied wall anchors before installing Surface Mount Installation the screw (predrill if required). CAUTION: Two people will be 5. Secure the wall bracket to the required for various steps of wall using the supplied 1½...
  • Page 14: Flush Mounted Installation - 2X8 Framing

    3. Use the supplied bubble level to level the fireplace within the framing, adjust as required. 4. Drive four supplied mounting screws through the four mount- ing holes located on the inside surface of the fireplace chassis, into wall studs (Figure 9). www.dimplex.com...
  • Page 15: Operation

    Fireplace Installation Figure 11 Figure 10 Front tray Front glass assembly Hooks (4) Mounts (4) Operation The manual controls for the elec- Figure 12 tric fireplace are located on the right side of the unit and inside the air intake slot (Figure 12). A.
  • Page 16: Remote Control

    C. Manual Control Buttons disconnect power and call The Manual Control Buttons oper- Dimplex customer service at ate the fireplace levels. The level 1-888-DIMPLEX is increased every time the “I” but- (1-888-346-7539).
  • Page 17 Operation fireplace levels sequentially (from 5. Press any button on the off): flames only; to flames and remote control within that 10 heat. seconds. This will synchro- nize the remote control and NOTE: There is a third level receiver. that does not change the output, before cycling back to flame only.
  • Page 18: Maintenance

    Accessories Contact your local authorized Dimplex dealer for these and other available accessories for your electric fireplace. Wall Switch Remote Control (WRCPF-KIT) Wall mounted remote for flame On/Off and thermostat control.
  • Page 19: Warranty

    Products, other than fireplace surrounds product. (mantels) and trims, covered by this limited warranty have been tested and What Dimplex will do in the event of a inspected prior to shipment and, subject defect to the provisions of this warranty, Dimplex...
  • Page 20 Warranty not commercially practicable or cannot place of business and all labour costs. be timely made, Dimplex may, in lieu of Such costs shall be the purchaser’s re- repair or replacement, choose to refund sponsibility. the purchase price for such product or What Dimplex and its dealers and service part.
  • Page 21: Replacement Parts

    Mounting Kit........9600760100RP Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 © 2013 Dimplex North America Limited...