Installation; Installing The Fireplace Shell - Montigo EP28-5 Installation & Operation Manual

5" b-vented gas fireplaces modular series
Table of Contents

Advertisement

Installing The Fireplace Shell

The fireplace may be installed in any location that is free of air con-
ditioning ducts, electrical wiring and plumbing. Safety, as well as ef-
ficiency of operation, must be considered when selecting the fireplace
location. Try to select a location that does not interfere with room
traffic, has adequate ventilation, and offers an accessible pathway for
B-Vent & Combustion Air Kit installation.
The fireplace dimensions are shown below:
19
C
Top View
37 1/2
Front View
Figure 1. Fireplace dimensions.
Clearances
The EP-28 Series clearances to combustible materials are:
Top*
Back
Sides
Floor
Mantle**
Recess Depth***
Flue
* Clearance from the top of the fireplace to
a combustible ceiling, within the fireplace
enclosure.
** Refer to page 5.
See Figure 2.
WARNING
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
XG0302C

Installation

14 3/4
5" B-Vent
4' B-Vent
9 1/2
31 1/4
Side View
12"
0"
1"
0"
6"
15"
1"
:
EP8-5 Modular Series Fireplace
Framing
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.
15 1/2*
37 1/2
*
When sheetrock is not used behind the fireplace, framing
depth may be reduced to 14 3/4"
Figure 2. Framing dimensions.
9 1/2
Figure 3. Corner Installation - framing dimensions.
36
38
1
9
14 3/4
37
1/2
53