Status Read Command - Sanyo PLC-XF47K Owner's Manual

Hide thumbs Also See for PLC-XF47K:
Table of Contents

Advertisement

Appendix

Status Read Command

Format
The command is sent from PC to the projector with
the format below;
'CR' [Command] 'CR'
Command: one character (refer to the command
table below.
The projector decodes the command and returns the
'Charactor string' with the format below;
Command
CR0
CR6
The tables on page 77 and 78 show the typical command lists for controlling the projector. Please consult your
local dealer for further information of other commands.
78
Projector
Function
Return
Status Read
Temperature Read
S1 S2 S3
Power On
00
Stand-by mode
80
Countdown
40
Cooling down
20
Power Malfunction
10
Cooling down at the temperature anomaly
28
Unable to receive the RC232C command.
02
Cooling down at Power Management mode
24
Power Management mode after Cooling down
04
Cooling down after the projector is turned off when the lamps
21
are out.
Stand-by mode after Cooling down when the lamps are out.
81
Stand-by mode after Cooling down at the temperature
88
anomaly.
S1 = Temperature at Sensor 1 (˚C)
S2 = Temperature at Sensor 2 (˚C)
S3 = Temperature at Sensor 3 (˚C)
(ex.) S1 = 12.3˚C, S2 = 23.4˚C, S3 = 34.5˚C
--> The projector displays "12.3 23.4 34.5"
(For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
Communication failure
?
Projector status

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xf47

Table of Contents