Operating Instructions - Dometic RM1350 User Manual

Refrigerator for lp-gas & electric operation
Hide thumbs Also See for RM1350:
Table of Contents

Advertisement

tURning on thE REfRigERatoR
!
WARNING
FIRE HAZARD. Before lighting the gas burner,
after that the RV has not been used for some
time, please check that the gas path between
the burner jet and the burner tube has not been
obstructed. Failure to heed this warning could
cause a fire resulting in personal injury.
gaS EqUiPmEnt aSSEmbly
BURNER MOUNTING
SCREWS
BURNER JET
BURNER TUBE .
SPARK ELECTRODE
1.
Check that all the manual gas valves are in the ON
position.
2.
Make sure that a continuous 12V DC supply is
available for the electronic control to function.
3.
Press the ON/OFF button.
4.
select operation mode:
-
auTO mode (aC and Gas)
Press the auTO/Gas mode selector button
(if not already on).
Gas mode (gas operation only)
-
Press the auTO/Gas mode selector button to turn
off the auTO mode (if not already off).
adjUSting thE thERmoStat
The adjustable thermostat ranges from 1 - 5 (5 = coldest tem-
perature setting).
after the initial start-up, adjust the thermostat by
pressing the TEMP. sET button repeatedly until the
desired setting is displayed.
The thermostat controls both the gas and electric operation.
Thus, it is not necessary to reset each time a different energy
source is employed.

oPERating inStRUctionS

SOLENOID VALVE
INLET FITTING
MANUAL SHUTOFF VALVE
Shown in open position
PRESSURE TEST PORT
-  -
icE makER
Rm1350im, Rm1350mim & Rm1350Wim
Before the ice maker can operate, make sure that:
The refrigerator is connected to 120 V aC .
The water valve supplying the refrigerator is turned on.
The ice level bail arm is in its fully down position.
Down
position
when the ice maker thermostat senses the preset temperature
for the ejection of the ice cubes, the fingers will start to rotate,
dumping any ice cubes and filling the mold with water.
when the storage container is full, the bail arm will come in
contact with the ice cubes. The bail arm cannot return to the full
down position and the ice production is stopped until the bin is
emptied, or ice cubes are removed.
To prevent water from splashing out of the mold assembly when
your recreational vehicle is moving, raise the bail arm to the full
"uP/OFF" position about 1-1/2 hours before departing. This will
allow the water in the mold to freeze.
WatER SUPPly
The water supply system must have a minimum pressure of
15 pounds per square inch gauge (psig). a 1/4" diameter water
line to the water valve should be used at the rear of the refrig-
erator. The water line must have a manual shutoff valve placed
where it is easily accessible.
The maximum water level is represented by a thin line. It is
essential that the water level does not exceed this line!
Maximum
water level
If necessary change the water flow by adjusting the water
supply, see the step-by-step instruction in the following section
aDjusTING ThE sIzE OF CuBEs.
Ice level
bail arm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents