Item
Condition
22. ALC meter
1) Menu No. : 87
start point
(Frequency : 14.1MHz)
Transmit
Zone max.
2) Menu No. : 88
Transmit
23. FM DEV
1) Menu No. : 89
Wide
(Frequency : 29.1MHz)
Transmit
Narrow
2) Menu No. : 90
Transmit
24. HF SWR
1) Menu No. : 118
protection
(Frequency : 14.1MHz)
Transmit
150Ω dummy connection
: Use a cable that is 1m long
25. SWR meter
1) Menu No. : 119
(SWR : 3)
(Frequency : 14.1MHz)
Transmit
150Ω dummy connection
: Use a cable that is approx.
10cm long
26. 50MHz
1) Menu No. : 120
SWR meter
(Frequency : 50.1MHz)
(SWR : 3)
Transmit
27. VHF SWR
1) Menu No. : 121
protection
(Frequency : 145.9MHz)
ANT : Open
Transmit
28. UHF SWR
1) Menu No. : 122
protection
(Frequency : 438.1MHz)
ANT : Open
Transmit
• Writing data : After items 5~8 and 12~28 have been adjusted;
1) Menu No. 124
2) [+] or [–] key : Push once time. Display "rEAdy" → "good" (If "nG" is displayed, enter data again.)
3) [CLR] key : Push once time.
29. AT detec-
1) Display f. : 51.990MHz
tion balance
Mode : CW
Power : 10W
Transmit
1200MHz Unit Transmitter Section
Item
Condition
1. TX IF gain
1) Display f. : 1270.000MHz
Mode : CW
Carrier : 0
Transmit
ADJUSTMENT (J TYPE)
Measurement
Test-
Unit
Terminal
equipment
Power
Rear
ANT1
meter
panel
Through
ANT2
type power
meter
150Ω dummy
Ammeter
ANT144
ANT430
Oscilloscope
Filter
TP1
(AMD)
Power
Rear
ANT1
meter
panel
Measurement
Test-
Unit
Terminal
equipment
Spectrum
Rear
ANT1.2G TX-RX3
analyzer
panel
Power
meter
TS-2000/B2000/2000X
TS-2000S/2000V/2000SX/2000VX
Adjustment
Unit
Parts
Method
Front
[+] key 1 push
panel
[+] key
Set the adjustment
or
value within the
[–] key
limit of the specifi ed
power.
[+] key 1 push
[+] key
Set the adjustment
or
value within the limit
[–] key
of the specifi ed cur-
rent.
Filter
VR2
Turn the VR2 to the
point where the
waveform on the os-
cilloscope changes
from high to low.
(Threshold point)
Adjustment
Unit
Parts
Method
Set the carrier level
at approx. 100mW.
L2
Power max.
L3
L9
Specifi cations / Remarks
(ALC meter lights up to 1)
(ALC meter zone max.)
4.3kHz±0.05kHz
2.2kHz±0.05kHz
40W±1W : S,SX
8W±0.5W : V,VX
(SWR meter lights up to 3
level.)
11A±0.25A : S,SX
9.0A±0.25A : V,VX
9.25A±0.25A : S,SX
7.0A±0.25A : V,VX
Specifi cations / Remarks
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-2000sTs-b2000Ts-sxTs-vxTs-2000xTs-v

Table of Contents