Kenwood reserves the right to make changes to any wise, for any purpose without the prior written permission products herein at any time for improvement purposes.
BEFORE USING THE SERVICE MANUAL ■ This service manual (SUPPLEMENT III) describes the • Refer to the table for the serial number of each trans- information of the changed PCBs in the TS-2000/TS- ceiver with this service manual. B2000/TS-2000X/ TS-2000S/TS-2000V/TS-2000SX/TS- •...
Page 9
If a part reference number is listed in a shaded box, K1 : TS-2000 (K) K2 : TS-B2000 (K) K3 : TS-2000X (K) that part does not come with the PCB. E1 : TS-2000 (E) E2 : TS-B2000 (E) E3 : TS-2000 (E2) E4 : TS-B2000(E2) E5 : TS-2000X (E)
Page 21
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (K/E TYPE) Transmitter Section Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 1. Final idling 1) Display f. : 14.100MHz DC. A Rear Final Check the default current Mode : USB...
Page 22
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (K/E TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 6. ALC 1) Menu No. : 00 DC V.M TX-RX1 Front [+] key Set the adjustment 2.7V±0.1V reference (Frequency : 14.1MHz)
Page 23
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (K/E TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 13. HF power 1) Menu No. : 68 Power Rear ANT1 Front [+] key Set the adjustment 100W±3W (Frequency : 14.1MHz)
Page 24
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (K/E TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 16. VHF power 1) Menu No. : 91 Power Rear ANT144 Front [+] key Set the adjustment 100W±3W (Frequency : 145.9MHz)
Page 25
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (K/E TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 22. ALC meter 1) Menu No. : 87 Power Rear ANT1 Front [+] key 1 push (ALC meter lights up to 1) start point (Frequency : 14.1MHz)
Page 26
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (K/E TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 2. MCF 1) Disconnect the cable from CN5. Tracking TX-RX3 CN15 TX-RX3 L320 Adjust the coils to (135.395MHz) Display f. : 1270.00MHz...
Page 27
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (J TYPE) Transmitter Section Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 1. Final idling 1) Display f. : 14.100MHz DC. A Rear Final Check the default current Mode : USB...
Page 28
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (J TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 6. ALC 1) Menu No. : 00 DC V.M TX-RX1 Front [+] key Set the adjustment 2.7V±0.1V reference (Frequency : 14.1MHz)
Page 29
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (J TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 13. HF power 1) Menu No. : 68 Power Rear ANT1 Front [+] key Set the adjustment 100W±3W : S,SX (Frequency : 14.1MHz)
Page 30
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (J TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 16. VHF power 1) Menu No. : 91 Power Rear ANT144 Front [+] key Set the adjustment 100W±3W : S,SX (Frequency : 145.9MHz)
Page 31
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (J TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 22. ALC meter 1) Menu No. : 87 Power Rear ANT1 Front [+] key 1 push (ALC meter lights up to 1) start point (Frequency : 14.1MHz)
Page 32
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT (J TYPE) Measurement Adjustment Item Condition Specifi cations / Remarks Test- Unit Terminal Unit Parts Method equipment 2. MCF 1) Disconnect the cable from CN5. Tracking TX-RX3 CN15 TX-RX3 L320 Adjust the coils to (135.395MHz) Display f. : 1270.00MHz...
Page 33
TS-2000/B2000/2000X TS-2000S/2000V/2000SX/2000VX ADJUSTMENT Adjustment Points (Upper Side) TC1 VR1 FILTER UNIT (X51-318) (AMD) FINAL UNIT (X45-384) (A/2) VR102 VR101 CN19 FRONT FILTER UNIT FINAL UNIT (A/2) TC1 : Null VR1,2,3,4,101,102 : Final idling current (HF/VHF) VR1 : Power frequency characteristic...
Page 57
FINAL POWER AMPLIFIER MODULE L309 C315 RA18H1213G-101 12R:0V 12R:13.66V 12T:1.53V 12T:13.42V SWITCHING R115 12ANT L7091CER CN14 12R:0V 12T:4.70V SWITCHING FINAL UNIT (HF) X45-384X-XX SWITCHING (A/2)-CN203 D3,4 HIGH-FREQUENCY RECTIFICATION FINAL UNIT (430) SWITCHING X45-384X-XX (B/2)-CN904 FINAL UNIT (HF) X45-384X-XX (A/2)-CN204 FINAL UNIT R:1.78V (430) T:0V...
Page 67
Unit 3712-3724, Level 37, Tower one Metroplaza, 223 Hing Fong Road, Bp 58416 Villepinte, 95944 Roissy Ch De Gaulle Cedex Kwai Fong, N.T., Hong Kong KENWOOD House, Dwight Road, Watford, Herts., 1 Ang Mo Kio Street 63, Singapore 569110 WD18 9EB United Kingdom...