Factory Reset; Power Up Quick Key Options - dbx DriveRack 480 User Manual

Complete equalization & loudspeaker management system
Hide thumbs Also See for DriveRack 480:
Table of Contents

Advertisement

DriveRack
In the unfortunate event that a reset is required, the DriveRack™ units offer you the option of performing a "Soft" or
"Hard" reset. The Soft Reset resets everything except user programs. The Hard Reset Procedure will reset all program-
mable information back to the factory defaults.
480 and 480R Factory ("Hard") Reset
• Press and Hold the STORE button on power-up until the following message appears:
• Pressing the PREV PAGE button will start a Factory Reset (All User Programs will become copies of the
Factory Programs, all Utility settings will be defaulted, and all Security settings will be defaulted)
Pressing the PROGRAM button will abort the Factory Reset sequence and the unit will reset normally.
480 and 480R Factory ("Soft") Reset.
Press and Hold the OTHER button at power-up until the following message appears:
• Pressing the PREVPAGE button will start a System Reset (All Utility settings will be defaulted.)
• Pressing the PROGRAM button will abort the System Reset sequence and the unit will reset normally.
481 and 482 Factory ("Hard") Reset
• Press and hold the ID DOWN button on power-up until the following message appears in the 7-Seg Display:
• Pressing the PROGRAM UP button will start a Factory Reset (All User Programs will become copies of the
Factory Programs, all Utility settings will be defaulted, and all Security settings will be defaulted)
Pressing any other button will abort the Factory Reset sequence and the unit will reset normally.
481 and 482 Factory ("Soft") Reset.
• Press and Hold the ID UP button on power-up until the following message appears in the 7-Seg Display:
• Pressing the PROGRAM UP button will start a System Reset (All Utility settings will be defaulted.)
Pressing any other button will abort the System Reset sequence and the unit will reset normally.
The DriveRack™ units offer several "Quick Key" options for initial power up and are as follow:
480 and 480R Power-Up Output Mute
Press and hold any of the mute buttons at power-up. All of the outputs will be muted when the program loads.
480 and 480R Change Initial Program Number
Press and hold <PROGRAM> at power-up until the following message appears:
"Use Wheel1 to" - "Change Restart"
Turning the PARAMETER 1 knob will select the program you wish to load at initial reset.
Press the PROGRAM button again when the selection is complete. Normal resetting will continue.
481 and 482 Power-Up Output Mute
Press and hold any of the mute buttons at power-up. All of the outputs will be muted when the program loads.
Note: 481 has no mute buttons so cannot perform this function.
481 and 482 Change Initial Program Number
Press and hold the PROGRAM DOWN button at power-up until the program number blinks in the display.
Use the PROGRAM UP and PROGRAM DOWN buttons to select the program you wish to load at initial reset.
Press the ID UP button when the selection is complete. Normal resetting will continue.
®
"! HARD RESET?"
"! SOFT RESET?"
A.2 Factory Reset
"HARD"
"SOFT "
A.3 Power Up Quick Key Options
- "Program Number"
DriveRack™ User Manual
Appendix A
93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Driverack 481Driverack 482Driverack 480r

Table of Contents