Download Print this page

Installing Gas Supply - Miller Electric Gas Cylinder Rack Owner's Manual

For renegade 180

Advertisement

4.

Installing Gas Supply

Tools Needed:
5/8, 1-1/8 in
5
8
6
7
OM-230 806 Page 4
.
DO NOT use Argon/Mixed gas reg-
ulator/flowmeter with CO
shielding
2
gas.
Argon Gas Or
Mixed Gas
!
Tipping
cause injury and damage. Do
not exceed maximum cylin-
der weight, diameter, and/or
height for this cylinder rack.
1
Strap
Obtain gas cylinder and use strap
to secure to cylinder rack so
cylinder cannot fall and break off
valve.
2
Cap
3
Cylinder Valve
2
Remove cap, stand to side of valve,
and open valve slightly. Gas flow
blows dust and dirt from valve.
Close valve.
4
Cylinder
3
5
Regulator/Flowmeter
Install so face is vertical.
6
Regulator/Flowmeter Gas
Hose Connection
7
Welding Power Source Gas
4
Hose Connection
Connect supplied gas hose to
regulator/flowmeter gas hose con-
nection.
8
Flow Adjust
Typical flow rate is 20 cfh (cubic
feet
per
manufacturer's recommended flow
rate.
1
.
Shown for securing gas cylinders
taller than 24 in. (610 mm).
equipment
can
hour).
Check
wire
Ref. 802 028 / 804 968-A

Advertisement

loading

This manual is also suitable for:

Mixed gas regulator 300237