Installing Wire Spool And Adjusting Hub Tension; Positioning Jumper Links; Installing Drive Roll And Wire Inlet Guide - Miller Electric Millermatic 250 Owner's Manual

Arc welding power source and wire feeder
Table of Contents

Advertisement

2-8. Installing Wire Spool And Adjusting Hub Tension

Tools Needed:
15/16 in

2-9. Positioning Jumper Links

3
1
OM-1308 Page 8
When a slight force is needed to turn spool, tension is set.
200 VOLTS
230 VOLTS
230 VOLTS
460 VOLTS
460 VOLTS
575 VOLTS
S-144 918-C
Use compression spring with
8 in (200 mm) spools.
220 VOLTS
380 VOLTS
415 VOLTS
S-144 916-A
S-144 915-A
2
Check input voltage available at
site.
1
Jumper Links Access Door
Open door.
2
Jumper Link Label
Check label – only one is on unit.
3
Input Voltage Jumper Links
Move jumper links to match input
voltage.
Close and secure access door.
Tools Needed:
3/8 in
Ref. ST-148 263-C
ST-072573-B