2-7. Installing Welding Gun

1

2-8. Installing Wire Spool And Adjusting Hub Tension

Tools Needed:
15/16 in
OM-1311 Page 12
4
2
3
When a slight force is needed to turn spool, tension is set.
1
Drive Assembly
2
Gun Securing Knob
3
Gun End
Loosen securing knob. Insert gun
end through opening until it bottoms
against drive assembly. Tighten
nut.
4
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
Close door.
Use compression spring with
8 in (200 mm) spools.