2-10. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit
Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length
In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC).

2-11. Selecting A Location And Connecting Input Power

200
220
50
45
80
70
8
10
93 (28)
75 (23)
8
10
18 in (457 mm)
for airflow
GND/PE
L1
Connect First
1
230
380
415
44
26
24
70
40
35
10
12
12
82 (25)
137 (42)
163 (50)
10
12
12
Have only qualified persons make
this installation.
1
Rating Label
Supply correct input power.
Y Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
GND/PE
L2
Size and ratings must comply with ap-
plicable codes. Install conductors in
conduit or equivalent into a deener-
gized line disconnect device.
460
575
22
17
35
25
10
12
329 (100)
313 (95)
10
12
S-0092J
ST-801 721
OM-1308 Page 9