2-10. Installing Wire Spool and Adjusting Hub Tension
2-11. Positioning Jumper Links
3
1
When a slight force is needed to turn spool, tension is set.
230 VOLTS
200 VOLTS
460 VOLTS
230 VOLTS
575 VOLTS
S-153 980
Use compression spring with
8 in (200 mm) spools.
S-144 916-A
2
Tools Needed:
15/16 in
ST-072573-B
Check input voltage available at
site.
1
Jumper Links Access Door
Open door.
2
Jumper Link Label
Check label – only one is on unit.
3
Input Voltage Jumper Links
Move jumper links to match input
voltage.
Close and secure access door.
Tools Needed:
3/8 in
802 476-A
OM-1320 Page 13