Care and cleaning
(continued)

Test run after care and cleaning

Turn on power supply after cleaning the air fi lter, dust box
and brush unit then perform a test run.
1
2
Press
again for approx. 1 second
Automatic operation stops.
3
Close the front panel (Check that it is closed)
If the front panel is open, the air fi lter may not function correctly.
4
Press
on the remote controller for 10 seconds
CHECK
or longer
is displayed in the remote controller display for approx 2 seconds.
Operation of the air fi lter is checked automatically for approx. 3 minutes.
<Display portion of indoor unit>
(Blue)
(Orange)
5
Check the lamp in the Indoor unit display
All lamps are turn off for normal.
DUST BOX and TIMER lamp blink. It may be a fault with the air fi lter setting.
Press
to turn off the lamp.
Perform removal and assembling of the air fi lter again.
Return to 4 after setting and check that the fi lter cleaning functions normally.
1110650159_(31-38)_EN.indd 31
1110650159_(31-38)_EN.indd 31
(Blue)
(Orange)
Illuminated in sequence
Page 30

When not used for a long time

1
Turns off power supply.
2
Remove the batteries from the remote
controller
Approx.
If left inserted, they may cause a leakage of
1 second
battery fl uid or power discharge.
Until it switches
to Automatic
operation
When restarting for use
1
Check that the indoor unit and outdoor unit
are clear
If blocked, performance may be impaired
or may not function.
2
Insert new batteries into the remote
controller and set the year, month, day and
time
3
Turns on power supply.