Operating in Manual Mode
Note: If the cartridge does not come out of the drive, remount the cartridge
8. Remove the cartridge from the drive.
9. Properly store the cartridge outside the LSM (refer to
Chapter
Dismounting a Cartridge from a 9840 Drive
To dismount a cartridge from a 9840 drive:
1. Ensure that the 9840 drive is not selected form the host.
2. Press the Unload switch.
3. After the tape rewinds, the cartridge ejects from the 9840 drive. Remove the
cartridge form the 9840 drive.
Returning the LSM to Online Status
To place the LSM online for automated operations:
1. Make sure that the drive shuttle Operate Handle indicator is on and the
handle is up.
2. Close and lock the LSM doors. The robot will perform an audit of the cells.
3-22
by releasing it from the shuttle latch under the right side of the
cartridge. Then push the cartridge into the drive and lower the
handle. If this fails, the tape leader might be dislodged and require
rethreading.
4).
"Storing Cartridges"
in