Closed defect summary
E_Ports in node descriptor.
Symptom—Default should be to have E_Ports
displayed. Default should be on and setting should be
some place obvious.
Delete, Change Seed Switch, UnMonitor, and Monitor
buttons are enabled at any level of the fabric tree;
fabric and switch.
Names import when unique preserves first entry, not
the last entry as designed.
Symptom—Will not have the Name expected on an
entity.
Fabric display not sorting properly.
Incorrect behavior is seen during port selection in
performance port picker.
Symptoms:
When an invalid port (device WWN) is selected,
the right selection arrow button is available but the
user is not able to select the invalid port.
When the user clicks on a port, holds the shift key
down, and then clicks some other port below it,
the entire range is not selected.
When a user selects a port [B-series switches in
interopmode 2] for the performance graphs and
moves it to the select bucket, the user will not be
able to add more ports from the available bucket
to the selected bucket.
Unmonitored Fabric cannot be re-monitored after the
seed switch password is changed.
Setup Tools configuration is not migrated from EFCM
to DCFM.
Symptom—Setup Tools configuration is not migrated
from EFCM to DCFM 10.0.2.
DCFM message "TI zones will be activated when
saving zone DB".
Symptom—After saving the zoning db, a DCFM
message appears saying that the TI zones will be
activated.
TI Zones are not becoming active after clicking
nl
Activate.
EGM license is prompted on HP StorageWorks 4/256
SAN Director.
28
Solution
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround—Make sure there are no duplicate
names between the import file and the application, or
duplicates in the file.
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround steps:
1.
Do not select invalid ports.
2.
Use the control button, and then select the range
of ports.
3.
Use the control button to select all ports that are
required at one time.
Fixed in DCFM 10.1.0
Workaround—Delete and rediscover the Fabric.
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround—Run cfgEnable from the CLI.
Fixed in DCFM 10.1.0