Closed defect summary
Active Zone Config tab shows inactive zones that were
added to existing active config.
Symptom—When the user adds inactive zones to
active zone config, the Active Zone Config tab shows
inactive zones immediately.
Compare/Merge: adding/merging zone or zone
config not moving zone/alias to RHS zone DB in some
scenarios.
Symptom—When user adds/merges zone or zone
config from LHS zone DB to RHS zone DB, the alias
and zone will not be moved to RHS view in some
scenarios.
Zoning dialog permitting creating zone and zone
config with Default Zoning reserved names.
Symptom—When the user enters Default Zoning
reserved name for creating zoning element on the
Zoning dialog, no warning message appears and the
zoning element will be created successfully on Zoning
dialog.
Added detached WWN-Name pairs and then
nl
performed discovery. The switch does not write name.
Symptom—Switch and switch port Names configured
before discovery will be overwritten with values
discovered on the switch.
Error messages enhancements.
User with Read-Only Reports privilege can delete a
report.
Compare/Merge dialog is not showing progress
bar/hourglass for any of the operation.
Symptom—When the user performs an operation in
the Compare/Merge dialog, the dialog does not
display the progress bar or hourglass for any of the
operation.
When an Access Gateway is connected to two fabrics
discovered in DCFM, only one of the fabrics displays
the Access Gateway connection.
Symptom—The customer will not be able to see the
Access Gateway connection details on all the fabrics
that are connected to it.
Help page is not completed in MK backup and Restore
Dialogs.
User cannot collect the Support information using the
Windows Batch File in the bin folder.
Symptom—User clicks on the supportsave batch
file in the bin folders and sees a command prompt
screen for just one second.
14
Solution
Fixed in DCFM 10.1.0
Workaround—Closing and relaunching dialog
displays proper information.
Fixed in DCFM 10.1.0
Workaround—Manually add alias member to RHS
side.
Fixed in DCFM 10.1.0
Workaround—Rename the zone element with valid
name and commit zone DB to destination.
Fixed in DCFM 10.1.0
Workaround—Discover switch and then assign Names
to switches and switch ports. The switch values control
the names in the application.
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround— Wait still the changes are reflected in
the Compare/Merge dialog.
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround—Collect the support save from
nl
SMC > Technical Support Information > Capture.

Advertisement

loading

This manual is also suitable for:

Brocade bladesystem 4/24Storageworks dcfm 10.1.0