28. Apply the 3 x 6 x 1100mm gasket to the
square side of the outlet port.
29. Attach (1) 3 x 15 x 700mm gasket to the outer
circular rims of each outlet port.
30. Mount the outlet port to the blower hous-
ing with (4)
"-18 x 1" hex bolts, (8)
5
16
flat washers, and (4)
figure 31).
outlet port
gasket
figure 31. Filter l-braces mounted to blower
housing.
31. Attach the filter l-braces to either side of the
outlet port on the blower housing with (6)
18 x 1" hex bolts, (12)
(6)
"-18 hex nuts.
5
16
32. secure the short filter brace support to the
back of the filter l-braces with (2)
hex bolts, (4)
" flat washers, and (2)
3
8
hex nuts (see figure 32).
short
Brace
support
figure 32. short filter brace support attached.
-26-
"
5
16
"-18 hex nuts (see
5
16
outlet ports
w/gaskets
Filter
l-Braces
"-
5
16
5
" flat washers, and
16
"-16 x
"
3
3
8
4
"-16
3
8
33. Attach the two long brace supports to the
filter braces with (4)
" flat washers, and (4)
3
8
shown in figure 33.
figure 33. long brace supports attached.
34. With assistance, position the rubber mount-
ing gaskets between the filter canisters and
the long brace supports, and secure the can-
isters with (8)
"-18 x
5
16
" fender washers (see figure 34).
5
16
gasket
rubber
gaskets
here
figure 34. Canister filters mounted to the long
support braces.
Model G0637/G0638 (Mfg. Since 04/12)
3
"-16 x
3
" hex bolts, (8)
8
4
"-16 hex nuts, as
3
8
" hex bolts and (8)
3
4
Mounting
Bolts