OPERATION AND CARE OF YOUR APPLIANCE
Young children should be carefully supervised when they are in the
same room as the appliance. Toddlers, young children and others
may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict
access to a fireplace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room
and away from hot surfaces.
Les jeunes enfants devraient être surveillés étroitement lorsqu'ils se trou-
vent dans la même pièce que l'appareil. Les tout petits, les jeunes enfants
ou les adultes peuvent subir des brûlures s'ils viennent en contact avec
la surface chaude. Il est recommandé d'installer une barrière physique
si des personnes à risques habitent la maison. Pour empêcher l'accès
à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure
empêchera les tout petits, les jeunes enfants et toute autre personne à
risque d'avoir accès à la pièce et aux surfaces chaudes.
Hinge Pin
NOTE: The gas supply line must be installed in accordance with building codes by a qualified
installer approved and/or licensed as required by the locality. In the Commonwealth of Massachu-
setts, installation must be performed by a licensed plumber or gas fitter.
Figure 1 -
Gas Control Compartment Access

Gas Controls/Control Compartment Access

The standard controls for appliance operation are located behind the hinged drop-down panel
below the appliance front glass enclosure panel (see Figure 1). Optional control switches are also
available (see Page 18 - Remote Wall Switch or Remote Control).
To open the control compartment access panel, actuate the spring-loaded magnetic catches secur-
ing the panel. First, depress the outer top right corner of the panel until the catch "pops" the door
free. Then, gently pull the door forward until the left top corner "pops" free, allowing the panel to
swing out and down to open.
To ease door closure, depress the catches to place them in their retracted position, then close
the door.
8
WARNING
AVERTISSEMENT
OFF/PILOT/ON (gas control knob)
HI/LO (flame height
control knob)
OFF/ON Switch
Piezo Igniter
Control
Compartment Access panel
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
On millivolt systems, the piezo igniter, HI/LO
flame adjustment knob, and pilot and main
gas OFF/ON control knob are located below
the glass panel enclosure. The gas valve for
electronic systems is also located below the
glass enclosure panel. See Figure 1.
Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and
operating your appliance determine if you have
a millivolt or electronic appliance. Familiarize
yourself with the gas control valve that your
appliance uses. Refer to Figure 1 for access
to the gas control valve.
Millivolt Appliances -
To light millivolt appliances refer to Figure
1. Detailed lighting instructions are found on
Pages 22 and 23. Millivolt appliance lighting
instructions may also be found on the pull out
lighting instruction labels attached to the gas
control valve.
Once the pilot is lit, the main burner may be
turned ON and OFF using a wall switch, remote
control or unit-mounted rocker switch. To
operate: Toggle the switch between its ON
and OFF positions.
If your millivolt appliance is equipped with an
optional remote switch kit (wall switch or remote
control) and the pilot is lit, the appliance main
Gas Flex Line
burner may be turned on and off using the
optional switch. When using an optional remote
Gas Valve
switch, turn off the standard OFF/ON switch.
NOTE: To prevent excessive resistance in
burner circuit (which can cause burner opera-
tion problems), only one burner control switch
should be wired to valve.
Millivolt Appliances - Appliances with
Millivolt systems will be fitted with the gas
control valve shown in Figure 2.
Electronic Appliances - Appliances with
electronic systems will be fitted with the
electronic valve shown in Figure 3.