OPERATION AND CARE OF YOUR APPLIANCE
Young children should be carefully supervised when they are in the
same room as the appliance. Toddlers, young children and others
may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict
access to a fireplace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room
and away from hot surfaces.
Les jeunes enfants devraient être surveillés étroitement lorsqu'ils se trou-
vent dans la même pièce que l'appareil. Les tout petits, les jeunes enfants
ou les adultes peuvent subir des brûlures s'ils viennent en contact avec
la surface chaude. Il est recommandé d'installer une barrière physique
si des personnes à risques habitent la maison. Pour empêcher l'accès
à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure
empêchera les tout petits, les jeunes enfants et toute autre personne à
risque d'avoir accès à la pièce et aux surfaces chaudes.
Main Gas
Shut-Off Valve
DFC Board
*CPI Switch - Switches from an
intermittent pilot mode to a stand-
ing pilot mode (a standing pilot
stays lit when the fireplace is off).
Main Gas
Shut-Off Valve
DFC Board
*CPI Switch - Switches from an
intermittent pilot mode to a stand-
ing pilot mode (a standing pilot
stays lit when the fireplace is off).
Main Gas
Shut-Off Valve
Main Gas
Shut-Off Valve
Figure 1 - Control Compartment Access
8
WARNING
AVERTISSEMENT
Burner Assembly
Pilot Assembly
Burner Assembly
ELECTRONIC MODELS
Battery
Gas Valve
Holder
CPI Switch*
*CPI Switch Positions
(o) = Intermittent Pilot Mode
(-) = Standing Pilot Mode
Battery
Gas Valve
Holder
CPI Switch*
Pilot Assembly
Burner Assembly
*CPI Switch Positions
(o) = Intermittent Pilot Mode
(-) = Standing Pilot Mode
Pilot Assembly
Burner Assembly
MILLIVOLT MODELS
Gas Valve
(Optional) Burner
Burner ON/OFF
Piezo
Switch (optional)
ON/OFF Switch
Gas Valve
(Optional) Burner
Piezo
ON/OFF Switch
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Pilot Assembly
Door Latch
Glass Door
Door Latch
Spring Latch
Door Latch
Glass Door
Spring Latch
Door Latch
Gas Controls/Control Compartment
Access
The gas controls can be found behind the hinged
drop-down panel.
To open the hinged drop-down panel, actuate
the spring loaded magnetic catches securing
the door. First, gently depress the upper right
top corner of the panel until the magnet catch
"pops" the door free. Then, gently pulling the
panel forward, disengage the left magnet catch
and allow the panel to swing down to open.
On millivolt systems, the piezo igniter, Hi/Lo
flame adjustment knob, and pilot and main gas
ON/OFF control knob are located in the control
compartment. On both millivolt and electronic
systems the gas valve is located in the control
compartment. See Figure 1.
Remove the bottom compartment door by
sliding the hinge pin, located at the door's left
side, to the right until it disengages from the
left corner post hole. Pull the door diagonally
to the left, away from the fireplace.
To ease door closure, depress the catches to
place them in their retracted position until they
stay there, then close the door.
Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and
operating your appliance determine if you have
a millivolt or electronic appliance.
Refer to Figure 1 for access to the gas control
valve. Millivolt appliances will be fitted with the
gas control valve shown in Figure 2.
Appliances with electronic systems will be fitted
with the electronic valve shown in Figure 3.
Familiarize yourself with the gas control valve
that your appliance uses.