Pump Operation; Priming; Operation; Restarts - GE OSMONICS TONKAFLO QS1800V Series Installation, Operation And Maintenance Manual

Centrifugal pumps with quiet , stainless steel vertically mounted, flow-cooled motors
Table of Contents

Advertisement

4.0

PUMP OPERATION

Review Section 2.0 (Tonkaflo Specifications) and Section 3.0 (Pump Installation) before operat-
ing your pump.
4.1

Priming

Prime the pump as noted in Section 3.5 (Pump Priming).
4.2

Operation

Operate the pump within its specified flow range. Failure to do so may damage the
motor or liquid end. Refer to the Performance Specifications (Section 2.2) or the per-
formance curve supplied with your pump.
CAUTION:
4.3
Restarts - IMPORTANT!
A maximum of 100 starts per day is recommended
Motors should be allowed to run one minute to dissipate heat build-up from starting
current
Do
not
run
pump
The pump shall not be operated with an inlet pressure less than
20 psi (1.4 bar).
Do not deadhead pump.
The pump shall not be operated below the minimum or above the
maximum
capacity
(Table 2.1, Pump Performance Summary).
Do not exceed 90°F (32°C) operating fluid temperature.
The pump may be flushed with sanitizing water provided no power is
supplied to the motor.
14
dry
or
without
specified
for
your
sufficient
heads.
particular
model