Specifications; Set-Up; Iii. Specifications; Iv. Set-Up - Banner American ValueLam 4500 Operating Instructions Manual

Table of Contents

Advertisement

Do not leave the laminator power on for extended periods while not in use.
Unplug the machine at the end of the day as a precaution against a possible
fire hazard.
Do not operate the laminator with a damaged power supply cord or plug.
Replace fuses only with same type rated 20, 250V and 1A, 250V fuses.
Contact your dealer for replacement fuses.
There are two (2) EMERGENCY STOP buttons on the laminator, one on each
side. Depressing one of these buttons will stop the rollers.

III. Specifications...

Operating Speed:
Power Requirements
Voltage:
Warm Up Time:
Power Fuse:
Motor fuse:
Maximum Laminating Dimensions
Thickness:
Width Capacity:
Net Weight:
Shipping Weight:

IV. Set-up...

Inspection:

Upon receipt of your ValueLam 4500, inspect the crate, the machine and all other contents of
the crate for shipping damage. Damage should be brought to the immediate attention of the
delivering carrier.
Power Requirements:
The ValueLam 4500 is designed to operate on a 110 Volt, 20 Ampere circuit. It will plug into a
standard 110 volt wall receptacle. You must ensure that the circuit is protected by a 20 Amp
circuit breaker.

Appropriate Location:

The laminator must be placed on a sturdy table or stand in a clean, well lit area with ample
space on all four sides of the laminator.
Adjustable to 5 fpm (2.54cm/sec.)
108-125 VAC, 50/60 hz
25-30 minutes
20 A
1A
¼" (6.35mm)
45" (1143mm)
183 lbs
383 lbs