Installing The Chassis Into A Telco Rack; Turning On The System - Bosch DIVAR DIP-6080-00N Quick Installation Manual

Divar ip 6000 2u series
Hide thumbs Also See for DIVAR DIP-6080-00N:
Table of Contents

Advertisement

DIVAR IP 6000 2U
3.4.5

Installing the chassis into a Telco rack

To install the chassis into a Telco type rack, use two L-shaped brackets on either side of the
chassis (four in total). First, determine how far the chassis will extend out the front of the
rack. Larger chassis should be positioned to balance the weight between front and back. If a
bezel is included on the chassis, remove it. Then attach the two front brackets to each side of
the chassis, then the two rear brackets positioned with just enough space to accommodate
the width of the Telco rack. Finish by sliding the chassis into the rack and tightening the
brackets to the rack.
3.5

Turning on the system

The last thing to be done is to provide input power to the system.
To turn on the system:
1.
2.
Bosch Sicherheitssysteme GmbH
Plug the power cord from the power supply unit into a high-quality power strip that offers
protection from electrical noise and power surges. We recommended using an
uninterruptible power supply (UPS).
Press the power button on the control panel to turn on the system.
Quick Installation Guide
System setup - hardware | en
2013.05 | V3 | DOC
15