Installing the outer rails to the rack

To install the outer rails to the rack
1.
2.
3.
4.
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The first is to lock the
system into place when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the system in place when fully extended from the rack. This
prevents the system from coming completely out of the rack when you pull it out for servicing.
3.4.4

Installing the chassis into the rack

To install the chassis into a rack
1.
2.
3.
4.
Warning!
!
Do not pick up the unit with the front handles. The handles are designed to pull the system
from a rack only.
Warning!
Stability hazard
!
Before sliding the unit out for servicing make sure that the rack stabilizing mechanism is in
place, or the rack is bolted to the floor. Failure to stabilize the rack can cause the rack to tip
over.
See also:
3.4.5

Installing the chassis into a Telco rack

To install the chassis into a Telco type rack, use two L-shaped brackets on either side of the
chassis (four in total). First, determine how far the chassis will extend out the front of the
rack. Larger chassis should be positioned to balance the weight between front and back. If a
bezel is included on the chassis, remove it. Then attach the two front brackets to each side of
the chassis, then the two rear brackets positioned with just enough space to accommodate
the width of the Telco rack. Finish by sliding the chassis into the rack and tightening the
brackets to the rack.
Bosch Sicherheitssysteme GmbH
Attach the longer section of the outer rail to the outside of the shorter section of the
outer rail. You must align the pins with the slides. Both ends of the outer rail must face
the same direction in order to be secured to the rack.
Adjust both sections of the outer rail to the proper length so that the rail fits snugly
within the rack.
Secure the longer section of the outer rail to the front of the rack with two M5 screws
and the shorter section to the rear side of the rack with two M5 screws.
Repeat steps for the remaining outer rail.
Confirm that chassis includes the inner rails and rail extensions. Also, confirm that the
outer rails are installed on the rack.
Line chassis rails with the front of the rack rails.
Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you
may have to depress the locking tabs when inserting). When the system has been pushed
completely into the rack, you should hear the locking tabs click.
(Optional) Insert and tightening the thumbscrews that hold the front of the system to the
rack.
Rack precautions
Quick Installation Guide
System setup - hardware | en