2. INSTALLATION

2.1.
R
EFERENCE
2.2.
S
A
ITING THE
The technical information and instructions provided herein below are intended for the
installer so that the unit may be installed correctly and safely.
S
TANDARDS
The installation and initial start up of the boiler must be by a CORGI Approved Installer in
compliance with the installation standards currently in effect, as well as with any and all local
health and safety standards i.e.. CORGI .
This appliance must be installed by a competent installer in accordance with current
Gas Safety Regulations (Installation & Use) 1996.
The installation of this appliance must be in accordance with the relevant requirements of
the current Gas Safety Regulations (Installation & Use) 1996, current Building Regulations,
the current I.E.E. Wiring Regulations, current Water Regulations/ Byelaws, in Scotland in
accordance with the Building Standards (Scotland - Consolidated) Regulations and Health
and Safety document No. 635 "Electricity at work regs. 1989" and in Ireland the local
Building Regulations (IE).
C.O.S.H.H
Materials used in the manufacture of this appliance are non-hazardous and no special
precautions are required when servicing.
Installation should also comply with the following British Standard Codes of Practice:The
PPLIANCE
appliance may be installed in any room or indoor area, although particular attention is
drawn to the requirements of the current I.E.E. Wiring Regulations, and in Scotland,
the electrical provisions of the Building Regulations applicable in Scotland, with
respect to the installation of the combined appliance in a room containing a bath or
shower.
Where a room-sealed appliance is installed in a room containing a bath or
shower the boiler and any electrical switch or appliance control, utilising mains
electricity should be situated so that it cannot be touched by a person using the
bath or shower.
The location must permit adequate space for servicing and air circulation around the
appliance as indicated in paragraph 2.4.
The location must permit the provision of an adequate flue and termination.
For unusual locations special procedures may be necessary.
BS 6798-1987 gives detailed guidance on this aspect.
A compartment used to enclose the appliance must be designed specifically for this
purpose. No specific ventilation requirements are needed for an installation within a
cupboard.
This appliance is not suitable for outdoor installation.
The type C appliances (in which the combustion circuit, air vent intake and
combustion chamber are air-tight with respect to the room in which the
appliance is installed) can be installed in any type of room.
There are no limitations with respect to ventilation and the volume of the room itself.
The boiler must be installed on a solid, permanent wall to prevent access to the
electrical parts (when live) through the aperture on the back frame.
Gas installations
Boilers of rated input
not exceeding 60 kW
Forced circulation hot
water system
Installation of gas hot water
supplies for domestic purposes
( 2 nd family gases)
Flues
Air supply
Treatment of water in domestic
hot water central heating systems
I.E.E. wiring regulations
Specification for expansion
vessels
Installation of L.P.G.
BS 6891
1988
BS 6798
1987
BS 5449
1990
BS 5546
1990
BS 5440-1
1990
BS 5440-2
1989
BS 7593
1992
BS 7671
1992
BS 4814
1990
BS 5482
1994
5